差分探頭|P7360A

更新時間:2024-09-07

產品型號:P7360A

產品報價:

產品特點:差分探頭|P7360A Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while

P7360A差分探頭|P7360A的詳細資料:

差分探頭|P7360A

差分探頭|P7360A

  • Signal Fidelity
    • >12.5 GHz Bandwidth (P7313, Typical)
    • >8.0 GHz Bandwidth (P7380A, Typical)
    • >6.0 GHz Bandwidth (P7360A, Typical)
    • >4.0 GHz Bandwidth (P7340A, Typical)
  • Extended Linear Dynamic Range
    • 1.25 Vp-p at 5x Attenuation (P7313)
    • 4 Vp-p at 25x Attenuation (P7313)
    • 2 Vp-p at 5x Attenuation (P7380A, P7360A, P7340A)
    • 5 Vp-p at 25x Attenuation (P7380A, P7360A, P7340A)
  • Low Probe Loading
    • DC Input Resistance
      • 100 kΩ Differential
      • 50 kΩ Single Ended
    • AC Loading
      • Zmin >200 Ω out to 10 GHz (P7313)
      • Zmin >290 Ω, 4 GHz to 8 GHz (P7380A, P7360A, P7340A)
  • Versatility
    • Make Differential or Single-ended (Ground-referenced) Measurements*1
    • Solder-down Capability
    • Handheld Probing with Variable Spacing and Compliance
    • Fixtured Probing
  • Interchangeable Tip-Clip™ Assemblies
    • Connect to a Variety of Devices
    • Economical
  • TekConnect® Interface

Applications

  • Examples Include, but are not Limited To:
    • PCI-Express I and II, Serial ATA II, USB 2.0, DDRII, DDRIII, Fireware 1394b, Rambus, XAUI

*1 For details, please see application note 60W-18344-0, “Making Single-ended Measurements with Differential Probes.”

Z-Active™ Probing Architecture Leads the Way for High-speed Probing Applications

Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while providing improved connectivity with low loading. The Z-Active architecture is a hybrid approach composed of a distributed attenuator topology feeding an active probe amplifier.

The Z-Active probes use a tiny passive probe tip element that is separate from the amplifier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal fidelity problems. However this architecture maintains high DC input resistance and presents a higher AC impedance than previous probe architectures. It accomplishes this while providing significant length between the probe body and the probe attachment point to the DUT. This architecture provides the best of both worlds: high DC impedance like existing active probes and the stable high-frequency loading of Z0 probes.

Signal Fidelity

You can be confident in the signal fidelity of your measurements because the Z-Active architecture provides:

  • High Bandwidth
  • Excellent Step Response
  • Low Loading
  • High CMRR
  • Extended Linear Dynamic Range

Extended Linear Dynamic Range

Many of today’s logic signals and serial bus signals require the capability to measure up to several volts peak to peak.  These voltage levels may easily be viewed with the Z-Active architecture probes (P7380A, P7360A, and P7340A) with the extended linear dynamic range.  With a 2.0 Vp-p linear dynamic input range at the 5x attenuation setting, you can accuray measure DDR II and III, Firewire 1394b, and PCI-Express I and II signals at reduced noise levels.  In addition the 25x attenuation setting’s linear dynamic input voltage range can be used up to 5.0 Vp-p for accessing even larger signal swings found during transition times.

Connectivity

The Z-Active probe design allows the probe to easily switch between soldered, handheld, or fixtured applications.

This family of probes uses Tip-Clip™ assemblies, an interchangeable probe tip system that enables customers to configure their probe with the optimal tip for their application. These detachable assemblies make it possible to replace a tip for a fraction of the cost formerly associated with such hardware changes. The several lengths and variable spacing of the assemblies provide flexibility for adapting to vias and other test points of differing sizes. With Tektronix Tip-Clip assemblies, Monday’s solder-in probe can become Tuesday’s handheld tool, simply by switching tips.

 

 如果你對P7360A差分探頭|P7360A感興趣,想了解更詳細的產品信息,填寫下表直接與廠家聯系:

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

滬公網安備 31011402002799號

主站蜘蛛池模板: 免费观看视频成人国产| 亚洲29p| 亚洲国产在线2o20| 国产亚洲精品福利视频| 欲香欲色天天综合和网| 爽好舒服好紧h野战| 特级黄色视频毛片| 中文字幕专区高清在线观看| 欧美zzzoooxxx| 国产精品色欲AV亚洲三区软件| 越南高清xxxxx18| 亚洲v日韩v欧美在线观看| 天天综合网天天综合色| 亚洲福利二区| 日韩欧美区| 在线成人精品国产区免费| 日本精品卡一卡2卡3卡四卡三卡| 国产亚洲精品久久久久久久软件 | 欧美ⅹxxxx18性欧美| 免费视频精品38| 国产精品一区二区资源| 国产亚洲精品久久久久久鸭绿欲 | 日韩黄色在线视频| 淫品色影院| 无码人妻丰满熟妇啪啪网不卡| 性亚洲无删减| 天堂综合| 日韩久草视频| 深夜 免费 视频| 日韩 亚洲 中文 图片 小说| 尤物国产在线精品三区| 欧美一级日韩| 久久婷婷丁香五月色综合啪免费| 成人区精品一区二区不卡AV免费| 在线亚洲精品视频| 亚洲图色在线| 污在线看| 四虎黄色网址| 深深激情网| 在线看91| 亚洲欧洲高清|